Use this form to perform line quality measurements on Loop Start ( LS) trunks that are connected to the AX controller, Analog Main Board, Analog Option Board, or ASU II.
Any new test conducted on a trunk overwrites the previous results with the latest results, however, the test results are also stored as maintenance logs. After you use the Line Measure Tool on a line, the columns in the form are updated with the results.
Use this form when performing the following tasks:
Before you can run line measurement tests, you must configure the system to support the tests. See Measuring LS Trunk Line Settings for instructions.
Parameter |
Description |
Line Quality Measurement |
|
Status |
Displays the status, date and time of the test that is selected in the bottom frame. See below for definitions of these fields. |
Date |
|
Time |
|
Test Type |
Displays the type of test performed. Individual Line Quality Test - Reports the loss level, Echo Return Loss ( ERL), and line quality for a specified trunk. Batch Line Quality Test - Reports the loss level, Echo Return Loss ( ERL), and line quality for all applicable trunks in the system. Individual Distortion/Echo Test - Measures non-linear distortion (for example, from clipping) of a specified LS trunk for each candidate balance circuit setting. Batch Distortion/Echo Test - Measures non-linear distortion (for example, from clipping) of all applicable LS trunks in the system for each candidate balance circuit setting. |
LMT Reports |
|
Date |
Month/day/year of the test. |
Time |
Hours:minutes:seconds of the test. |
PLID |
Physical location identifier of circuit that the test applies to. |
Recommended Setting |
If the test is successful, the following information is provided:
If you have enabled the Automatic Setting option in the Analog Trunks form of the trunk, these settings are automatically applied to the specified trunk circuits. |
Status |
An assessment of the overall quality of the line (GREEN, YELLOW, RED).
|
Other |
If the test fails, an error message is displayed in this field. |
ERL |
Minimum Echo Return Loss ( ERL) measured on the line. |